EMAIL US
scanner@hanslaser.com
UltraScan I 第1世代 | 7mm | 10mm① | 10mm② | 10mm③ | 14mm | 20mm | 30mm | 50mm |
Input Beam Aperture (mm) | 7 | 10 | 10 | 10 | 14 | 20 | 30 | 50 |
Beam Displacement (mm) | 9.98 | 12.54 | 12.54 | 12.54 | 16.42 | 25.25 | 35.61 | 62.25 |
Tracking Error (ms) | 0.12 | 0.18 | 0.14 | 0.16 | 0.23 | 0.45 | 0.7 | 1 |
Repeatability (µrad) | <2 | <2 | <3 | <2 | <2 | <2 | <2 | <2 |
Offset Drift (µrad/K) | <20 | <15 | <15 | <15 | <15 | <15 | <15 | <15 |
Gain Drift (ppm/K) | <100 | <80 | <80 | <80 | <80 | <80 | <80 | <80 |
Long-term drift over 8 hours (mrad) | <0.4 | <0.3 | <0.4 | <0.15 | <0.3 | <0.3 | <0.3 | <0.3 |
1% of full scale (ms) | 0.19 | 0.4 | 0.3 | 0.35 | 0.65 | 0.8 | 1.2 | 1.5 |
10% of full scale (ms) | 0.6 | 1.2 | 1 | 1.1 | 1.6 | 2.5 | 4.5 | 6.5 |
Positioning Speed (m/s) | 25 | 10 | 20 | 15 | 10 | 5 | 3 | 1 |
Typical Scan Angle (°) | ±25 | |||||||
Gain Error (mrad) | <5 | |||||||
Zero Offset (mrad) | <5 | |||||||
Nonlinearity (%) | <0.4 | |||||||
Power Requirements | ±15VDC, ≥3A | |||||||
Communication Protocol | 16Bit :XY2-100 20Bit:ST2-100 | |||||||
Operation Temperature (℃) | 25±10 | |||||||
Weight (kg) | 1.6 | 1.9 | 1.9 | 1.9 | 2.3 | 5 | 5.2 | 8.8 |
UltraScan II 第2世代 | 10mm | 14mm | 20mm | 30mm |
Input Beam Aperture (mm) | 10 | 14 | 20 | 30 |
Beam Displacement (mm) | 12.54 | 16.42 | 25.25 | 35.53 |
Tracking Error (ms) | 0.12 | 0.15 | 0.35 | 0.6 |
Repeatability (µrad) | <2 | <2 | <2 | <2 |
Offset Drift (µrad/K) | <12 | <12 | <12 | <12 |
Gain Drift (ppm/K) | <50 | <50 | <50 | <50 |
Long-term drift over 8 hours (mrad) | <0.15 | <0.15 | <0.15 | <0.15 |
1% of full scale (ms) | 0.3 | 0.35 | 0.7 | 1.1 |
10% of full scale (ms) | 0.8 | 0.9 | 2.4 | 4.4 |
Positioning Speed (m/s) | 18 | 14 | 6 | 4 |
Typical Scan Angle (°) | ±25 | |||
Gain Error (mrad) | <5 | |||
Zero Offset (mrad) | <5 | |||
Nonlinearity (%) | <0.4 | |||
Power Requirements | ±15VDC, ≥3A | |||
Communication Protocol | 16Bit :XY2-100 | |||
Operation Temperature (℃) | 25±10 | |||
Weight (kg) | 1.9 | 2.3 | 5 | 5.2 |